Model | Output Data | Motor Data | ||||||||
Output Speed RPM (Aprox.) |
Output Torque Nm | Actuator Self Locking |
Rated Power HP |
No. of Poles |
Rated Current AMP (Aprox.) |
Power Factor FL |
Effi. % (FL) |
Mounting Base As per IS 9334 |
||
Rated | Adj Range | |||||||||
M30 | 10,15,20 30,40 65,90 120,150 |
30 | 10-30 | Yes Yes Yes No |
0.16 0.25 0.35 0.50 |
4 2 2 2 |
0.42 0.57 0.71 1.00 |
0.75 0.76 0.79 0.78 |
53 58 62 67 |
F10 |
M60 | 10,15,20 30,40 65,90 120,150 |
60 | 20-60 | Yes Yes Yes No |
0.16 0.25 0.50 1.00 |
4 2 2 2 |
0.42 0.57 1.00 1.70 |
0.75 0.76 0.78 0.82 |
53 58 67 75 |
F10 |
M80 (M0) |
1O to 70 80 to 140 190 to 365 |
80 | 25-80 | Yes Yes No |
1.00 3.00 3.00 |
4 2 2 |
1.80 4.55 4.55 |
0.78 0.83 0.83 |
76 81 81 |
F10 |
M120 | 10,15,20 30,40 65,90 120,150 |
120 | 40-120 | Yes Yes Yes No |
0.25 0.50 1.00 1.50 |
4 2 2 2 |
0.58 1.00 1.70 2.40 |
0.75 0,78 0.82 0.82 |
58 67 75 79 |
F10 |
M150 | 10,15,20 30,40 65,90 120,155 |
150 | 50-150 | Yes Yes Yes No |
0.35 0.75 1.50 2.00 |
4 2 2 2 |
0.77 1.33 2.40 3.10 |
0.74 0.79 0,82 0.86 |
61 73 79 78 |
F10 |
M200 (M1) |
10 to30 40 to 60 80 to 120 |
200 | 60-200 | Yes No No |
1.00 2.00 3.00 |
4 4 2 |
1.80 3.30 4.55 |
0.78 0.80 0.83 |
76 78 81 |
F14 |
M250 | 10,15,20 30,40 65,90 120,150 |
250 | 80-250 | Yes Yes Yes No |
0.50 1.00 2.00 3.00 |
4 2 2 2 |
1.04 1.70 3.10 4.55 |
0.72 0.82 0.86 0.83 |
69 75 78 81 |
F14 |
M300 | 10,15,20 30,40 65,90 120,150 |
300 | 100-300 | Yes Yes Yes No |
0.75 1.50 3.00 5.00 |
4 2 2 2 |
1.40 2.40 4.55 7.20 |
0.78 0.82 0.83 0.87 |
72 79 81 82 |
F14 |
M500 | 10,15,20 30,40 65,90 120,150 |
500 | 160-500 | Yes Yes Yes No |
1.00 2.00 5.00 7.50 |
4 2 2 2 |
1.80 3.10 7.20 10.20 |
0.78 0.86 0.87 0.89 |
76 78 82 84 |
F14 |
M600 | 10,15,20 30,40 65,90 120,150 |
600 | 200-600 | Yes Yes Yes No |
1.50 3.00 5.00 7.50 |
4 2 2 2 |
2.50 4.55 7.20 10.20 |
0.81 0.83 0.87 0.89 |
76 81 82 84 |
F14 |
M1000 | 10,15,20, 30,40,60, 80, 120 |
1000 | 300-1000 | Yes Yes Yes No |
1.5 3 5 10 |
6 4 2 2 |
2.9 4.6 7.2 14 |
0.69 0.82 0.87 0.88 |
76 81 82 85 |
F16 |