Spink Controls

We are India’s leading Instrumentation company driven by latest Technologies

TUBULAR LEVEL INDICATOR

SERIES : SC / L – 001
Gauge is fitted between two end fittings through gland packing. The gauge is mounted parallel to tank so as to form a close loop causing tank liquid to seek its level in the gauge. The Gauge Glass is protected with ‘C’ channel. End fitting has built-in isolating valve, drain valve & vent plug.


INSTALLATION
Side mounted through tank nozzles, having matching counter
flanges / threads, ensuring that CC distance between nozzles
corresponds with CC distance (R) of the gauge.


Categories: level, Level Transmitter



ENGINEERING SPECIFICATION:
  • Gauge : HW Borosilicate Glass 16 / 19mm OD (25mm for Viscous Liquids)
  • End Fitting MOC : CS / SS 304 / SS 316 / PP / PTFE
  • End Block Type : W / O Valve / Offset NV with or W / O Auto Ball Check
  • Guards : CS / SS304 / FRP C- Channels
  • Gland MOC : CI / SS 316 / PP
  • Packing : PTFE
  • Process conn. : 3/4 ” / 1 ” Flanged (Table D / ANSI 150#) or BSP Screwed
  • Vent / Drain : Plug / Ball valve
  • Scale : Aluminium Engraved
  • CC Dist. : 1500mm in Single Length, Large CCD’s thru’ Coupler
  • Visibility : CC Dist – 150mm
  • Maximum Temp. : 200°C (Metallic) / 70°C (PP)
  • Test Pressure : 10 Kg/cm² (Metallic) / 2 Kg/cm²