Phone No. : +91-998 7522 984
Email id : paraag@ppsmumbai.com
Phone No. : +91-998 7522 984
Email id : paraag@ppsmumbai.com
FEATURES :
Model | PDB-300E |
---|---|
Measuring Component | CuSO4 NaOH HCHO pH |
Measuring Range | CuSO4·5H2O : 1 - 20g/L NaOH : 1 - 20g/L 37%HCHO : 1 - 20mL/L pH : 1 - 14pH |
Analysis Time | 4 item, Less than 10 min. |
Sampling Volume / 1cycle | Applox. 5mL |
Data Display | 320 x 240 dots graphical LCD |
Control Method | Pulse-width modulation type proportional control |
Relay Outputs | Proportional control output, SPST Normal Open : 4 Concentration Alarm output, SPST Normal Open : 1 Error Output, SPST Normal Close (Fail Safe) : 1 Buzzer Output, 100VAC Normal Open : 1 Warning Light Output, 100VAC Normal Open : 1 |
Relay Capacity | 250VAC 1A / 30VDC 1A (Resistive Load) |
Recorder | 6-dot chart recorder (100mm) |
Dimensions | 600(W) x 1400(H) x 450(D) mm |
Features
Model | OZ-50 |
---|---|
Sensor | LS-840LL TS-100 |
Flow Cell | SH-100RO |
Terminal Box | TR-50A |
Measuring Component | Dissolved Ozone |
Measuring Range | 0 - 10mg/L |
Effective Measuring Range | 0.1 - 10mg/L |
Repeatability | Within 5% of Full Scale |
Linearity | Within 5% of Full Scale |
Analog Output | 4 - 20mADC (Isolated, Max. Load 900ohm) |
Relay Contacts | Low and High concentration alarm Normal Open Error alarm Normal Close (Fail safe) |
Relay Capacity | 250VAC, 1A |
Power Requirement | 90 - 240VAC |
Power Consumption | Applox. 10W |
Dimensions | 96(W) x 96(H) x 213(D) mm |
Panel Cutting Size | 92.5(W) x 92.5(H) mm |
Weight | 2kg |
Features
Name | Dissolved Hydrogen Monitor |
---|---|
Model | BIH-50D |
Sensor | LS-1540Y |
Flow Cell | DH-30FC |
Mearsuring Method | Membrane Poralographic Cell |
Range | 0.00 - 20.00µg/L (Minimum Indication 0.01μg/L) 0.00 - 10.00 mg/L (Minimum Indication0.01mg/L) 0.0 - 2000 % (Minimum Indication0.1% without analog output) |
Repeatability | Within ±5%FS (Under fixed conditions) |
Response Time (T90) | Less than 30 sec. (100%H2 gas → 0%H2gas) |
Indicator | 4-digit LCD |
Analog Output | 4 - 20 mADC, Maximum Load 650Ω |
Power Voltage | 90 - 264VAC 50/60Hz |
Power Comsumption | Approx. 5W |
Contact Output | High and Low alarm output: Normal Open Memtenance-in-progress: Normal Open Error output, Normal Open |
Contact Capacity | AC250V 3A DC30V 3A (Resistive load) |
Solution Temperature | 5 - 40°C |
Temperature Compensation Range | 5 - 40°C |
Operating Environment | 5 - 40°C, 20 - 80%Rh (no condensation) |
Fluid Pressure | Maximum 0.2MPa (2 kgf/cm2) gauge pressure |
Flow Rate | 0.2 - 2.0 L/min. |
Calibration | Zero calibration – Electrical Zero or pure N2 gas Span calibration – Atmospere of 100%H2gas |
Instalation Style | Indoor panel mounting |
Dimensions | 96(W) x 96(H) x 121(D) mm |
Panel Cutting Size | 92(W) x 92(H) mm |
Weight Approx. | 0.5kg |
Digital Communication | RS-232C (Optional specification) |
Standard Accessaries | Membrane (M-1540T) : 1 box (10pcs) Electrolyte (EL-1540T) : 1btl (50mL) |
Membrane Polarographic Cell (Lead-free)
Can be used from low concentration to high concentration by double cathode adoption.
Easy maintenance by cartridge type membrane
Atmospheric pressure compensation function
DIN 96 Size instrument
Name | Dissolved Oxygen Monitor |
---|---|
Model | BDO-50D |
Sensor | Model : OX-30BY Cathode : Au Body : PP Wetted Material : PP, FEP DH Influence (100%) : Equivalent -4g/L CO2 Influence (100%) : Equivalent 15µg/L |
Flow Cell | DO-30FC |
Mearsuring Method | Membrane Polarographic Cell |
Measuring Range | DO : 0.00µg/L - 20.00mg/L SAT : 0.000 - 200.0% (without analog output) O2 : 0.000 - 25.00% (without analog output) |
Repeatability | Within ±2%FS |
Response Time (T90) | Less than 15 sec. |
Display | 4-digit LCD |
Analog Output | 4 - 20 mADC (Isolated, Max. Load 650ohm) |
Power Requirment | 90 - 264VAC 50 / 60Hz |
Power Comsumption | Approx. 5W |
Alarm Output | Low and High Relay contact, Normal Open Capacity : 250VAC 3A, 30VDC 3A (Resistive Load) |
Solution Temperature | 0 - 45°C |
Temperature Compensation Range | -1.0 - 50.0°C |
Operating Enviroment | -10 - 50, 90%Rh or Less (no condensation) |
Flow Rate | 100 - 300mL/min. |
Calibration | Zero calibration : Electrical Zero or Zero solution Span calibration : Atmospere or Air saturated water Atmospheric pressure : Manual calibration function |
Instalation Style | Indoor panel mounting |
Dimensions | 96(W) x 96(H) x 121(D) mm |
Panel Cutting Size | 92(W) x 92(H) mm |
Weight Approx. | 0.5kg |
Digital Communication | RS-232C (Optional specification) |
Standard Accessaries | Membrane (M-1150T) : 1box (4pcs) Electrolyte (EL-1150T) : 1btl (50mL) |
Pollution Protection Systems Mumbai Pvt. Ltd (PPSMPL) Company established in “1994”. PPSMPL Designs, develops, manufactures and supplies highly reliable, cost effective instruments and systems as well as services for Gas Detection and Monitoring. Apart from systems suppliers PPSMPL also provides solutions