Others

FEATURES :

  • It is a controller of the electroless copper plating liquid used at the production lines such as print boards
Model PDB-300E
Measuring Component CuSO4
NaOH
HCHO
pH
Measuring Range CuSO4·5H2O : 1 - 20g/L
NaOH : 1 - 20g/L
37%HCHO : 1 - 20mL/L
pH : 1 - 14pH
Analysis Time 4 item, Less than 10 min.
Sampling Volume / 1cycle Applox. 5mL
Data Display 320 x 240 dots graphical LCD
Control Method Pulse-width modulation type proportional control
Relay Outputs Proportional control output, SPST Normal Open : 4
Concentration Alarm output, SPST Normal Open : 1
Error Output, SPST Normal Close (Fail Safe) : 1
Buzzer Output, 100VAC Normal Open : 1
Warning Light Output, 100VAC Normal Open : 1
Relay Capacity 250VAC 1A / 30VDC 1A (Resistive Load)
Recorder 6-dot chart recorder (100mm)
Dimensions 600(W) x 1400(H) x 450(D) mm

Features

  • Membrane Polarographic cell
  • Not necessary of mechanical cleaning mechanism
  • Low interference from combined chlorine
Model OZ-50
Sensor LS-840LL
TS-100
Flow Cell SH-100RO
Terminal Box TR-50A
Measuring Component Dissolved Ozone
Measuring Range 0 - 10mg/L
Effective Measuring Range 0.1 - 10mg/L
Repeatability Within 5% of Full Scale
Linearity Within 5% of Full Scale
Analog Output 4 - 20mADC (Isolated, Max. Load 900ohm)
Relay Contacts Low and High concentration alarm Normal Open
Error alarm Normal Close (Fail safe)
Relay Capacity 250VAC, 1A
Power Requirement 90 - 240VAC
Power Consumption Applox. 10W
Dimensions 96(W) x 96(H) x 213(D) mm
Panel Cutting Size 92.5(W) x 92.5(H) mm
Weight 2kg

Features

  • Membrane Polarographic Cell
  • The calibration adopts the atmospheric calibration method without using a hydrogen standard gas.
  • Direct-reading Instrument
  • Automatic Temperature Compensation
  • DIN 96 Size Instrument
Name Dissolved Hydrogen Monitor
Model BIH-50D
Sensor LS-1540Y
Flow Cell DH-30FC
Mearsuring Method Membrane Poralographic Cell
Range 0.00 - 20.00µg/L (Minimum Indication 0.01μg/L)
0.00 - 10.00 mg/L (Minimum Indication0.01mg/L)
0.0 - 2000 % (Minimum Indication0.1% without analog output)
Repeatability Within ±5%FS (Under fixed conditions)
Response Time (T90) Less than 30 sec. (100%H2 gas → 0%H2gas)
Indicator 4-digit LCD
Analog Output 4 - 20 mADC, Maximum Load 650Ω
Power Voltage 90 - 264VAC 50/60Hz
Power Comsumption Approx. 5W
Contact Output High and Low alarm output: Normal Open
Memtenance-in-progress: Normal Open
Error output, Normal Open
Contact Capacity AC250V 3A DC30V 3A (Resistive load)
Solution Temperature 5 - 40°C
Temperature Compensation Range 5 - 40°C
Operating Environment 5 - 40°C, 20 - 80%Rh (no condensation)
Fluid Pressure Maximum 0.2MPa (2 kgf/cm2) gauge pressure
Flow Rate 0.2 - 2.0 L/min.
Calibration Zero calibration – Electrical Zero or pure N2 gas
Span calibration – Atmospere of 100%H2gas
Instalation Style Indoor panel mounting
Dimensions 96(W) x 96(H) x 121(D) mm
Panel Cutting Size 92(W) x 92(H) mm
Weight Approx. 0.5kg
Digital Communication RS-232C (Optional specification)
Standard Accessaries Membrane (M-1540T) : 1 box (10pcs)
Electrolyte (EL-1540T) : 1btl (50mL)

Membrane Polarographic Cell (Lead-free) Can be used from low concentration to high concentration by double cathode adoption. Easy maintenance by cartridge type membrane Atmospheric pressure compensation function DIN 96 Size instrument

  • Membrane Polarographic Cell (Lead-free)
  • Can be used from low concentration to high concentration by double cathode adoption.
  • Easy maintenance by cartridge type membrane
  • Atmospheric pressure compensation function
  • DIN 96 Size instrument
Name Dissolved Oxygen Monitor
Model BDO-50D
Sensor Model : OX-30BY
Cathode : Au
Body : PP
Wetted Material : PP, FEP
DH Influence (100%) : Equivalent -4g/L
CO2 Influence (100%) : Equivalent 15µg/L
Flow Cell DO-30FC
Mearsuring Method Membrane Polarographic Cell
Measuring Range DO : 0.00µg/L - 20.00mg/L
SAT : 0.000 - 200.0% (without analog output)
O2 : 0.000 - 25.00% (without analog output)
Repeatability Within ±2%FS
Response Time (T90) Less than 15 sec.
Display 4-digit LCD
Analog Output 4 - 20 mADC (Isolated, Max. Load 650ohm)
Power Requirment 90 - 264VAC 50 / 60Hz
Power Comsumption Approx. 5W
Alarm Output Low and High Relay contact, Normal Open
Capacity : 250VAC 3A, 30VDC 3A (Resistive Load)
Solution Temperature 0 - 45°C
Temperature Compensation Range -1.0 - 50.0°C
Operating Enviroment -10 - 50, 90%Rh or Less
(no condensation)
Flow Rate 100 - 300mL/min.
Calibration Zero calibration : Electrical Zero or Zero solution
Span calibration : Atmospere or Air saturated water
Atmospheric pressure : Manual calibration function
Instalation Style Indoor panel mounting
Dimensions 96(W) x 96(H) x 121(D) mm
Panel Cutting Size 92(W) x 92(H) mm
Weight Approx. 0.5kg
Digital Communication RS-232C (Optional specification)
Standard Accessaries Membrane (M-1150T) : 1box (4pcs)
Electrolyte (EL-1150T) : 1btl (50mL)

Pollution Protection Systems Mumbai Pvt. Ltd (PPSMPL) Company established in “1994”. PPSMPL Designs, develops, manufactures and supplies highly reliable, cost effective instruments and systems as well as services for Gas Detection and Monitoring. Apart from systems suppliers PPSMPL also provides solutions

Contact Us

: +91-998 7522 984

: paraag@ppsmumbai.com