Portable Gas Detector

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Sulphur Dioxide Detector (SO2)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :   0 – 100 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :   At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :   Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :   -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :    0 – 95% RH Non - Condensing
  Accuracy      +/- 1% FSD
  Resolution :    1ppm
  Response Time :    T90 < 40 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :    Max. 2 to 3 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Ammonia Detector (NH3)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 100 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :   -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :    0 – 95% RH Non - Condensing
  Accuracy      +/- 10 of Test Gas Concentration
  Resolution :    1ppm
  Response Time :    T90 < 60 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Arsine Detector (AsH3)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 1 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :   -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :    0 – 95% RH Non - Condensing
  Accuracy      +/- 10 of  Test Gas Concentration
  Resolution :    0.1ppm
  Response Time :    T90 < 30 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Chlorine Detector (CL2)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 20 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :  -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :   0 – 95% RH Non - Condensing
  Accuracy      +/- 10 of Test Gas Concentration
  Resolution :    0.1ppm 
  Response Time :    T90 < 25 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Carbon Dioxide Detector (ClO2)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 0 – 1 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :  -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :   0 – 95% RH Non - Condensing
  Accuracy     +/- 10 of Test Gas Concentration
  Resolution :    0.03ppm   
  Response Time :   T90 < 60 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Carbon Dioxide Detector (CO2)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 5000 ppm OR ( 0 – 5% V/V.)
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :  -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :   0 – 95% RH Non - Condensing
  Accuracy     +/- 10 of Test Gas Concentration
  Resolution :   1ppm OR ( 1% V/V.)  
  Response Time :   T90 < 20 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 5 to 8 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EeEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Carbon Monoxide Detector (CO)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 0 – 20/50 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :   -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :    0 – 95% RH Non - Condensing
  Accuracy      +/- 1% FSD
  Resolution :    1ppm
  Response Time :    T90 < 40 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  In Board Filter :   To remove H2S, SO2, & Acid gases.
  Sensor Life :  Max. 2 to 3 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 20 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :   -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :    0 – 95% RH Non - Condensing
  Accuracy      +/- 10 of  Test Gas Concentration
  Resolution :    1ppm
  Response Time :    T90 < 60 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Fluorine Detector (FL)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 1 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :  -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :   0 – 95% RH Non - Condensing
  Accuracy      +/- 10 of Test Gas Concentration
  Resolution :    1ppm 
  Response Time :    T90 < 80 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Hydrogen Sulphide Detector (H2S)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 0 – 10 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :  -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :   0 – 95% RH Non - Condensing
  Accuracy     +/- 1% FSD
  Resolution :    1ppm   
  Response Time :   T90 < 60 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  In Board Filter :    To remove SO2 & Acid gases
  Sensor Life :  Max. 2 to 3 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Hydrogen Chloride Detector (HCL)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 20/30 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :   -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :    0 – 95% RH Non - Condensing
  Accuracy      +/- 10 of Test Gas Concentration
  Resolution :    1ppm
  Response Time :    T90 < 30 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Hydrogen Cyanide Detector (HCN)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 0 - 20/30 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :   -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :    0 – 95% RH Non - Condensing
  Accuracy      +/- 10 of  Test Gas Concentration
  Resolution :    1ppm
  Response Time :    T90 < 30 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Hydrazine Detector (N2H4)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 1 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :  -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :   0 – 95% RH Non - Condensing
  Accuracy      +/- 10 of Test Gas Concentration
  Resolution :    0.01ppm 
  Response Time :    T90 < 30 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Nitrogen Dioxide Detector (NO2)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 0 – 20/50 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :  -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :   0 – 95% RH Non - Condensing
  Accuracy     0 - 20/50
  Resolution :    1ppm   
  Response Time :   T90 < 40 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 to 3 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Nitric Oxide Detector (NO)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 25/100/250/500 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :   -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :    0 – 95% RH Non - Condensing
  Accuracy      +/- 1% FSD
  Resolution :    1ppm
  Response Time :    T90 < 40 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 to 3 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Ozone Detector (O3)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 1/5 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :   -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :    0 – 95% RH Non - Condensing
  Accuracy      +/- 10 of  Test Gas Concentration
  Resolution :    0.01ppm
  Response Time :    T90 < 30 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Phosgene Detector (COCL2)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 1 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :  -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :   0 – 95% RH Non - Condensing
  Accuracy      +/- 10 of Test Gas Concentration
  Resolution :    0.1ppm 
  Response Time :    T90 < 30 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Silane Detector (SiH4)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 0 – 50 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :  -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :   0 – 95% RH Non - Condensing
  Accuracy     +/- 10 of Test Gas Concentration
  Resolution :    1ppm   
  Response Time :   T90 < 60 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Sulphur Dioxide Detector (SO)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 1 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :  -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :   0 – 95% RH Non - Condensing
  Accuracy      +/- 1% FSD
  Resolution :    1ppm 
  Response Time :    T90 < 40 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

APPROVALS :

  • Tested for Intrinsically safe as per IS 5780-2002{IEC-60079-11(1999)}
  • Tested for Performance as per IS 9000 (ERTL WEST)
  • Tested by CENTRAL INSTITUTE OF MINING & FUEL REASERCH LAB.(CMRI)
  • Approved for EEx ia IIC T4/T6
  • BIS Certificate No: - CM / L – 7449687 as per IS: 5780
  • CCE Approval No: -A/P/HQ/MH/104/518(P55545)

PPS make Portable Tetrahydrothiophene Detector (THT)

      TECHNICAL SPECIFICATION :
  Dimension :   130mm x 67mm (4.5” x 2.6” x 1.6”)
  Weight  :    450 gms. (With Batteries)
  Accessories :    Standard: - Carring Case Batt. Charger
   Optional: - Aspirator adaptor
  Measurement  Range :    0 – 0 – 50 ppm
  Display  :    Liquid Crystal Display (LCD)
  Standard Alarm Levels  :    At TLV
  Optional Alarm Levels :    As per specification
  Alarm Indication :    Pulsating / Continuous red LED with audible, 90 db at 1 Meter
  Battery   :    Standard: Rechargeable 4 x AA cells
   Optional: Disposable 
  Battery Life  :   12 – 15 hrs. Continuous
  Oper. Temperature :  -10 deg C to 50 deg C. (14 deg F to 122 deg F)
  Humidity  :   0 – 95% RH Non - Condensing
  Accuracy     0 – 20/50 ppm
  Resolution :    1ppb   
  Response Time :   T90 < 30 Sec.
  Setting :   Zero/ Span accessible from outside
  Sensor Type :   Electrochemical
  Sensor Life :  Max. 2 years (in fresh air)

Pollution Protection Systems Mumbai Pvt. Ltd (PPSMPL) Company established in “1994”. PPSMPL Designs, develops, manufactures and supplies highly reliable, cost effective instruments and systems as well as services for Gas Detection and Monitoring. Apart from systems suppliers PPSMPL also provides solutions