Our Products - Epoxy Finish Paint
TECHNICAL DATA SHEET |
Product Description |
This is two pack epoxy coating for metal and concrete surfaces . It is Amine / Amide cured coating to be
used as top coat. |
Recommended Uses |
Ideally suitable for use in varied conditions as a top coat on suitable Epicor Epoxy Primer . |
PRODUCT SPECIFICATION |
Mixing Ratio |
Base : Hardener
2 : 1 |
Colour |
All Shades as per customer requirement. |
Finish |
Glossy |
Pot Life |
6 hrs at 30 �C & 65 % Relative Humidity |
Volume Solids |
40 % � 3 |
Flash point |
More than 24 �C |
Recommended DFT |
30 � 5 microns per coat |
Covering Capacity |
12 to 14 sq.mtrs / ltr |
(Theoretical) |
- |
Drying Time |
Surface dry – 1 to 2 hrs at 30 �C & 65 % Relative Humidity
Hard Dry – 8 - 10 hrs max at 30 �C & 65 % Relative Humidity
Fully cured – 7 days |
Recoating Time |
8 – 10 hrs. at 30 �C & 65 % Relative Humidity |
Method of Application |
Brush / Conventional Spray / Airless Spray |
Thinner recommended |
‘ Epicor ’ Thinner |
Shelf life |
12 months under normal storage conditions in original sealed containers. |
Surface Preparation |
Suitably primed surface free from oil , grease , moisture and any other foreign matters. |
Remarks 1. Application Data |
Method |
Pressure ( Atm) |
Nozzle |
Thinner |
Thinner volume |
Brush |
- |
- |
Epicor Thinner |
0 – 5 % |
Conventional Spray |
3– 4 |
|
Epicor Thinner |
5 – 10 % |
Airless Spray |
4 – 5 |
0.018 inch to 0.025 inch |
Epicor Thinner |
0 – 5 % |
2. Don’t use below 10 �C
3. Stir well before and while using.
4. Film thickness other than indicated also possible.
5. Mix 15 mins before use.
Safety Precautions : |
Provide sufficient ventilation while working with solvent based paints in confined spaces and stagnant air. |
Keep the material away from heat , spark and direct flame |
Avoid inhalation of solvent vapour or paint mist by using facial mask .Use goggles and gloves to protect against direct contact of paint with
skin and eyes. |
In case of contamination , rinse with fresh running water and seek medical help at once. |
Follow local & national safety rules. |
Special Comments : |
Thinner consumption and actual coverage of paint depends on the site conditions. |
Stir the paint well before painting and while painting if necessary. |
Material should be stored at 30 �C temperature in dry place.
|