Distance measuring photoelectric sensors

Product Family

OADM 12
Characterstics
  • Smallest laser distance sensor
  • Measuring range can be limited
  • Sealed housing
  • Compact and smooth surface
  • Suppression of dirt and cleaning agents
Dimension:12,4 x 37 x 34,5 mm
  • measuring Distance:16 ... 120 mm
  • Resolution:2 μ m
response time: < 0,9 ms Output: 4 ... 20 mA 0 ... 10 V
Specific Characterstics Incorrect measurements are suppressed, the output remains at the last measured value for up to 30 ms
OBDM 12
Characterstics :
Difference sensor for sensing steps, changes in distance, distance windows or tolerance ranges
Dimension: 12,4 x 37 x 34,5 mm
measuring Distance: 16 ... 120 mm
response time: < 1 ms Output: PNP NPN
Specific Characterstics Step height, differences ranges to be evaluated set using Teach-in Teach-in using cabling or button
OADM 13
Characterstics :
  • Large measuring distance in a small housing
  • Measuring range can be
  • Spot or line laser beam
Dimension: 13,4 x 48,2 x 40 mm
measuring Distance: 50 ... 550 mm
Resolution: 10 μm
response time: < 0,9 ms Output: 4 ... 20 mA 0 ... 10 V RS 485 / RS 232
Specific Characterstics Incorrect measurements are suppressed, the output remains at the last measured value for up to 30ms
FADK 14
Characterstics :
  • Red light point source LED
  • Measuring range can be Limited
  • IO-Link
Dimension: 14,8 x 43 x 31 mm
measuring Distance: 50 ... 400 mm
Resolution: 0,1 mm
response time: < 5 ms Output: 4 ... 20 mA 0 ... 10 V
Specific Characterstics
  • An alarm output indicates an incorrect measurement or if the object is outside of the measuring range
  • Information on due maintenance can be retrieved
OADM 20
Characterstics :
  • Measuring range can be limited
  • Spot or line laser beam
Dimension: 20,6 x 65 x 50 mm
measuring Distance: 30 ... 1000 mm
Resolution: 4 μm
response time: < 0,9 ms Output: 4 ... 20 mA 0 ... 10 V RS 485
Specific Characterstics
  • An alarm output indicates an incorrect measurement or if the object is outside of the measuring range
  • Input for synchronizing
  • Laser diode can be switched on/off
OADM 20
Characterstics :
  • Line beam
  • Increased vibration immunity
  • Increased ambient light immunity 100 klux
  • Suitable for outdoor applications
Dimension: 20,6 x 65 x 50 mm
measuring Distance: 50 ... 1000 mm
Resolution: 10 μm
response time: < 2,5 ms Output: 4 ... 20 mA 0 ... 10 V
Specific Characterstics Missing measurement signals or incorrect measurements are suppressed
OADM 21
Characterstics :
  • High resolution at large measuring distance
  • Measuring range can be limited
  • Spot or line laser beam
Dimension: 20,4 x 135 x 45 mm
measuring Distance: 100 ... 1000 mm
Resolution: 10 μm
response time: < 5 ms Output: 4 ... 20 mA 0 ... 10 V
Specific Characterstics
  • An alarm output indicates an incorrect measurement or if the object is outside of the measuring range
  • Input for synchronizing measurements
  • Laser diode can be switched on/off
OADM 250
Characterstics :
  • High resolution
  • Measurement up to 4 m independent of colors
  • Alarm output
  • Measuring range can be limited
Dimension: 25,4 x 66 x 51 mm
measuring Distance: 0,5 ... 4 m
Resolution: 1,2 mm
response time: < 10 ms Output: 4 ... 20 mA 0 ... 10 V
Specific Characterstics An alarm output indicates an incorrect measurement or if the object is outside of the measuring range
OADM 260
Characterstics :
  • Large measuring range up to 13 m
  • Alarm output
  • Measuring range can be limited
Dimension: 25,4 x 66 x 51 mm
measuring Distance: 0,5 ... 13 m
Resolution: 5 mm
response time: < 10 ms Output: 4 ... 20 mA 0 ... 10 V
Specific Characterstics An alarm output indicates an incorrect measurement or if the object is outside of the measuring range
OADM 260
Characterstics :
  • Large measuring range up to 13 m
  • Alarm output
  • Measuring range can be limited
Dimension: 25,4 x 66 x 51 mm
measuring Distance: 0,5 ... 13 m
Resolution: 5 mm
response time: < 10 ms Output: 4 ... 20 mA 0 ... 10 V
Specific Characterstics An alarm output indicates an incorrect measurement or if the object is outside of the measuring range